PRAXAIR INC -- NITROGEN -- 6830-01-431-0639
=====================  Product Identification  =====================

Product ID:NITROGEN
MSDS Date:12/01/1992
FSC:6830
NIIN:01-431-0639
=== Responsible Party ===
Company Name:PRAXAIR INC
Address:39 OLD RIDGEBURY RD
City:DANBURY
State:CT
ZIP:06817-0001
Country:US
Info Phone Num:203-794-5782
Emergency Phone Num:203-794-5782/800-424-9300(CHEMTREC)
CAGE:0LV01
=== Contractor Identification ===
Company Name:PRAXAIR, INC.
Address:39 OLD RIDGEBURY RD
Box:City:DANBURY
State:CT
ZIP:06810-5113
Country:US
Phone:800-772-9247; 800-PRAXAIR
CAGE:0LV01

=============  Composition/Information on Ingredients  =============

Ingred Name:NITROGEN
CAS:7727-37-9
RTECS #:QW9700000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
ACGIH TLV:ASPHYXIANT; 9596

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INGEST:GAS @NORMAL TEMP/PRESURE.SKIN
    ABSORPT:NO EVIDENCE OF ADVERSE EFFECTS FROM AVAI
    INFO.INHAL:ASPHYXIANT.MODERATE CONC MAY CAUSE
    HEAD,DROWS,DIZZ,EXCITATION,EXCESS SALIVATION,VOMIT,UNCONSC.LACK OF
    O XY CAN CAUSE DEATH.SKIN/EYE:NO HARMFUL EFFECT EXPECTED FROM
    VAP.LIQ MAY CAUSE SKIN FROSTBITE.
Effects of Overexposure:NO EVIDENCE OF ADVERSE EFFECTS FROM AVAIL
    INFO.CONTACT W/LIQUID MAY CAUSE FROSTIBE.
Medical Cond Aggravated by Exposure:THE TOXICOLOGY & PHYSICAL & CHEM
    PROPERTIES OF MATL DO NOT SUGGEST THAT OVEREXPO IS LIKELY TO
    AGGRAVATE EXISTING MEDICAL CONDITIONS.

=======================  First Aid Measures  =======================

First Aid:INGEST:GAS @NORM TEMP/PRESSURE.SKIN:FOR LIQ EXPO IMMED WARM
    FROSTBITE AREA W/WARM H2O(NOT TO EXCEED 105F).MASSIVE EXPO REMOVE
    CLOTH WHILE SHOWERING W/WARM H2O.CALL DR.INHAL:REMOVE TO FRESH
    AIR.GIVE AR T RESP IF NOT BREATH.GIVE OXY IF BREATHDIFFI.CALL
    DR.EYE:SPLASH CONTAM IMMED FLUSH THOROUGHLY W/H2O FOR @LEAST
    15MINS.SEE DR PREFERABLY OPHTHALMOLOGIST IMMED.DR:NO SPECIFIC
    ANTIDOTE.TREAT SHOULD(SUP)

=====================  Fire Fighting Measures  =====================

Autoignition Temp:Autoignition Temp Text:NONE
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:NITROGEN CANNOT CATCH FIRE.USE MEDIA APPROPRIATE
    FOR SURROUNDING FIRE.
Fire Fighting Procedures:EVACUATE ALL PERSONNEL FRM DANGER AREA.IMMED
    DELUGE CNTNRS W/WATER SPRAY FRM MAXIMUM DISTANCE UNTIL COOL THEN
    MOVE CNTNRS AWAY FROM FIRE AREA W/O RISK.
Unusual Fire/Explosion Hazard:GAS CANT CATCH FIRE.CNTNR MAY RUPTURE DUE
    TO HEAT OF FIRE.NO PART OF CNTNR SHOULD BE SUBJ TO TEMP
    >52C(125F).MOST CNTNR ARE DESIGNED TO VENT CONTENTS WHEN (SUP)

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE ALL PERSONNEL FRM DANGER AREA.USE
    SCBA WHERE NEEDED.SHUT OFF LEAK W/O RISK.VENTI AREA/MOVE LEAK CNTNR
    TO WELL VENTI AREA.TEST AREA ESPECIALLY CONF AREA FOR SUFF OXY
    CONTENT PRIOR TO PERMITTIN G REENTRY OF PERSONNEL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:HI PRESSURE GAS.USE PIPE/EQPMT ADEQUAT
    DESIGNED FOR W/STAND PRESSURES TO BE ENCOUNTERED.CAN CAUSE RAPID
    SUFFOCATION DUE TO OXY DEFF.
Other Precautions:STORE/USE W/ADEQU VENTI.CLS VALVE WHEN NOT IN
    USE/EMPTY.WHEN 2/MORE GAS/LIQ GAS MIX HAZ PROPERTIES MAY COMBINE TO
    CREATE ADDN UNEXPECT HAZ.OBTAIN/EVALUATE SAF INFO FOR EA COMPO BEF
    PRODUCE MIXTURE.CON SULT INDUST HYG/TRAIN PERSON WHEN(SUPPL)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED UNDER NORMAL USE.HOWEVER AIR
    SUPPLIED RESPIRATORS ARE REQUIRED WHILE WORKING IN CONF SPACES
    W/PRODUCT.RESPIRATORY PROTECTION USE MUST CONFORM TO OSHA RULES
    SPECIFIED IN 29CFR1910.134.
Ventilation:LOC EXHAU-USE IF NECESSARY TO PREVENT BUILD UP O OXY DEFIC
    ATM.MECHANICAL(GENERAL):ACCEPTABLE.
Protective Gloves:PREFERRED FOR CYL HNDLG
Eye Protection:SELECT IAW OSHA 29CFR1910.133
Other Protective Equipment:METATARSAL SHOES FOR CYL HNDLG.SELECT IAW
    OSHA 29CFR1910.132/1910.133.
Work Hygienic Practices:BE SURE TO READ/UNDERSTAND ALL LABELS/OTHER
    INSTRUCTIONS SUPPLIED W/ALL CNTNR OF PRODUCT.NEVER WORK ON
    PRESSURIZED SYST.
Supplemental Safety and Health
1STAID:BE DIRECTED @CONTROL OF SYMP/CLINICAL CONDITION. FIRE/EXPLO
    HAZ:THEYRE EXPO TO ELEVATED TEMPS. OTHER PRECAUT:MAKE SAF
    EVALUATION OF END PRODUCT.REMEMBER GAS/LIQ HAVE PROPERTIES WHICH
    CAN CAUSE  SER INJURY/DEATH.RECOMMEND PAMPHLET P-1BRM COMPRESS GAS
    ASSOC INC,1725 JEFF DAVIS HWY,SUITE 1004,ARLINGTON,VA22202.

==================  Physical/Chemical Properties  ==================

HCC:G3
Boiling Pt:B.P. Text:-320F,-196C
Melt/Freeze Pt:M.P/F.P Text:-346F,-210C
Decomp Temp:Decomp Text:NP
Vapor Pres:GAS
Vapor Density:0.967
Spec Gravity:GAS
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NA
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS GAS AT NORMAL TEMPERATURE &
    PRESSURE
Percent Volatiles by Volume:100
Corrosion Rate:NP

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
UNDER CERTAIN CONDITIONS NITROGEN CAN REACT VIOLENTYLY
    W/LITHIUM,NEODYMIUM,TITANIU,OZONE.
Stability Condition to Avoid:NEVER WORK ON PRESSUREIZED SYS.IF LEAK
    CLOSE CYL VALVE BLOW DOWN SYS BY VENTING TO SAF PLACE,THEN REPAIR
    LEAK.
Hazardous Decomposition Products:NONE

====================  Disposal Considerations  ====================

Waste Disposal Methods:SLOWLY RELEASE INTO ATMOSPHERE.DISCARD ANY
    PRODUCT,RESIDUE,DISPO CNTNR OR LINER IN ENVIRON ACCEPTABLE MANNER
    IN FULL COMPLIANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.